Chapter 8 Carbon & Alloy Steels - Welding Filler Metals
[
Back ] [ Home ] [
Up ] [ Table of Contents ] [ Next ]
COVERED ALLOY
STEEL ARC WELDING ELECTRODES - MECHANICAL PROPERTIESa
|
|
Tensile Strength min |
Yield Strength mind |
% Elongation |
|
AWS A5.5b |
ksi |
MPa |
ksi |
MPa |
min |
|
E7010-X |
70 |
480 |
57d |
390d |
22 |
| E7011-X |
70 |
480 |
57d |
390d |
22 |
| E7015-X |
70 |
480 |
57d |
390d |
25 |
| E7016-X |
70 |
480 |
57d |
390d |
25 |
| E7018-X |
70 |
480 |
57d |
390d |
25 |
| E7020-X |
70 |
480 |
57d |
390d |
25 |
| E7027-X |
70 |
480 |
57d |
390d |
25 |
| E8010-X |
80 |
550 |
67 |
460 |
19 |
| E8011-X |
80 |
550 |
67 |
460 |
19 |
| E8013-X |
80 |
550 |
67 |
460 |
16 |
| E8015-X |
80 |
550 |
67 |
460 |
19 |
| E8016-X |
80 |
550 |
67 |
460 |
19 |
| E8018-X |
80 |
550 |
67 |
460 |
19 |
| E8016-C3 |
80 |
550 |
68-80 |
470-550 |
24 |
| E8018-C3 |
80 |
550 |
68-80 |
470-550 |
24 |
| E9010-X |
90 |
620 |
77 |
530 |
17 |
| E9011-X |
90 |
620 |
77 |
530 |
17 |
| E9013-X |
90 |
620 |
77 |
530 |
14 |
| E9015-X |
90 |
620 |
77 |
530 |
17 |
| E9016-X |
90 |
620 |
77 |
530 |
17 |
| E9018-X |
90 |
620 |
77 |
530 |
17 |
| E9018-M |
90 |
620 |
68-80 |
540-620 |
24 |
| E10010-X |
100 |
690 |
87 |
600 |
16 |
| E10011-X |
100 |
690 |
87 |
600 |
16 |
| E10013-X |
100 |
690 |
87 |
600 |
13 |
| E10015-X |
100 |
690 |
87 |
600 |
16 |
|
|
Tensile Strength min |
Yield Strength mind |
% Elongation |
|
AWS A5.5b |
ksi |
MPa |
ksi |
MPa |
min |
| E10016-X |
100 |
690 |
87 |
600 |
16 |
| E10018-X |
100 |
690 |
87 |
600 |
16 |
| E10018-M |
100 |
690 |
88-100 |
610-690 |
20 |
| E11015-X |
110 |
760 |
97 |
670 |
15 |
| E11016-X |
110 |
760 |
97 |
670 |
15 |
| E11018-X |
110 |
760 |
97 |
670 |
15 |
| E11018-M |
110 |
760 |
98-110 |
680-760 |
20 |
| E12015-X |
120 |
830 |
107 |
740 |
14 |
| E12016-X |
120 |
830 |
107 |
740 |
14 |
| E12018-X |
120 |
830 |
107 |
740 |
14 |
| E12018-M |
120 |
830 |
108-120 |
745-830 |
18 |
| E12018-M1e |
120 |
830 |
108-120 |
745-830 |
18 |
| a.
The value shown are for specimens which are tested in the as-welded
condition, except for the following electrodes that are in the stress- |
| relieved
condition E7018-W, E8016-C3, E8018-C3, E8018-NM, E8018-W, E9018-M, E10018-M,
E11018-M, E12018-M., E12018-M1. |
| See
AWS A5.5 for more details. The "M" classifications shall meet the
requirements of equivalent strength EXX18-X classifications when |
| tested
on AC. |
| b.
The letter suffix "X" as used in the table stands for all the suffixes (A1,
B1, B2, etc.) |
| c.
Yield strength may be increased 5000 psi (35 MPa) max for 3/32 in. (2.4 mm)
for "M" classifications. |
| d.
For the as-welded condition, the required yield strength is 60 ksi (415 MPa). |
| e.
The minimum UTS for the E12018-M1 classification is nominally 120 ksi (830
MPa). However, the required UTS may be other than |
| 120
ksi (830 MPa) as agreed between supplier and purchaser. |
| |
| [
Go to Top ] |
|